Einphasige Eisenbahntransformatoren ET1KOL**, mit Harz gefüllt
The technical solution was worked out bearing in mind the application of the transformers in the systems for protective separation of electric heaters for heating up EOR crossovers from supply devices near the tracks. The transformers are adjusted for fastening in hanging position, in the EGC-102 boxes near the tracks.
The fastening slots are placed in accordance with the standard hole spacing used in railway devices.
Produkt für:
Detaillierte Informationen:
Design | Isolating transformers ET1KOLŻ are produced in accordance with requirements of EN/IEC 61558-2-4 |
---|---|
Insulation class |
E(120oC) |
Climatic class /environmental class |
C2/E1 |
Ambient temperature | 10oC |
Protection degree | IP 00 |
Protection class | II |
Frequency | 50 Hz |
Primary voltage | 220 V or 230 V |
Secondary voltage | 220 V or 230 V |
Terminals | screw terminals with cross section 10 mm2 |
Fastening | by means of angles |
Technische Skizze
![]() |
![]() |
![]() |
Standard design | ||
![]() |
||
Connection diagram |
Dimensionstabelle
Technical data of single-phase isolating transformers fro railway engineering ET1KOL
Type | Power [kVA] |
L [mm] |
B [mm] |
H [mm] |
L1 [mm] |
L2 [mm] |
B1 [mm] |
H1 [mm] |
d [mm] |
e [mm] |
f [mm] |
g [mm] |
Weight [kg] |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ET1KOLŻ - 1,8 | 1,8 | 200 | 210 | 295 | 168 | 105 | 128 | 210 | 85 | 170 | 30 | 9 | 21 |
ET1KOLŻ - 2,5 | 2,0 | 200 | 235 | 280 | 200 | 105 | 138 | 235 | 85 | 170 | 30 | 11 | 28 |
Note:
Manufacturer reserves the right to make changes resulting from the continuous development of products offered.
If requested in advance, it is possible to manufacture transformer in other version.