Glättungsdrossel ED2W
Smoothing chokes ED2W are usually applied in output circuits of rectifiers. They allow a significant reduction of pulsation of rectified output current. In practice, smoothing chokes are often combined with capacitors and form LC filters.
The following table lists only the sample parameters of some manufactured chokes. After the previous agreement there is a possibility to design chokes with parameters other than those given in the table.
Produkt für:
- Eisenbahnindustrie
- Schwerindustrie
- Leistungselektronik
- Qualität der Elektrizität
- Erneuerbare Energiequellen
Detaillierte Informationen:
Design | Chokes are produced in accordance with standards : EN/IEC 60076-6; EN/IEC 61558-2-20 |
---|---|
Insulation class |
F(155oC) - standard |
Climatic class / Environmental class |
C1/E0 - land design; C2/E1 - maritime design |
Ambient temperature | 40oC |
Protection degree | IP 00 |
Pulsation content | < 10% - standard |
Pulsation frequenccy | 300 Hz - standard |
Rated voltage | up to 750 V (230 V standard) |
Overload | 110% In |
Terminals | screw terminal blocks or cable lugs or copper bus bars |
Fastening | by means of angles |
Technische Skizze
Standard design |
Dimensionstabelle
Technical data of sample designs of smoothing chokes ED2W
Item | Choke type | Inductance [mH] |
Current [A] |
L [mm] |
B [mm] |
H [mm] |
d [mm] |
e [mm] |
f [mm] |
Weigh [kg] |
---|---|---|---|---|---|---|---|---|---|---|
1 | ED2W-2 x 1/70 | 2 x 1 | 70 | 120 | 110 | 160 | 100 | 78 | 8 x 12 | 6,4 |
2 | ED2W-2 x 0,05/260 | 2 x 0,05 | 260 | 120 | 120 | 160 | 100 | 78 | 8 x 12 | 6,2 |
3 | ED2W-2 x 0,025/340 | 2 x 0,025 | 340 | 160 | 155 | 220 | 110 | 115 | 10 x 15 | 13 |
4 | ED2W-2 x 0,05/500 | 2 x 0,05 | 500 | 200 | 190 | 266 | 140 | 145 | 10 x 15 | 30 |
5 | ED2W-2 x 0,03/1265 | 2 x 0,03 | 1265 | 280 | 260 | 362 | 240 | 166 | 10 x 15 | 58 |
Note:
Producent zastrzega sobie prawo wprowadzania zmian wynikających z ciągłego rozwoju oferowanych wyrobów.
Możliwe jest wykonanie dławika w innej wersji po wcześniejszym uzgodnieniu.
Dla wykonania klimatyczno/środowiskowego C2/E1 w oznaczeniu należy podać dodatkowo literę "M"